NEW QUESTION 93
The NetEco management system adopts a large-capacity design architecture, which can support access to a large number of devices, and supports the use of a single X86 server to achieve access to () 10,000 test points. At the same time, the system operates smoothly, and the CPU utilization is not higher than () ?
- A. 100, 90
- B. 100, 70
- C. 50, 90
- D. 50, 70
Answer: A
NEW QUESTION 94
The difference between traditional power frequency machine and high frequency machine is: () (multiple choice)/
- A. Different types of bypass devices
- B. Different rectification methods
- C. The output must have a built-in step-up transformer
- D. All of the above are true
Answer: B,C
NEW QUESTION 95
NetCol5000-A025H half-cabinet row-level inverter air-cooled precision air conditioner, NetCol5000-A042H full-cabinet row-level air-cooled inverter precision air conditioner, NetCol8000-C 2.0 series room-level refrigerated underwater air supply precision air conditioner adopts a 7-inch touch-mode color screen, which can be Intuitively and vividly display unit operation information.
- A. True
- B. False
Answer: A
NEW QUESTION 96
UPS products such as APM and NR need to be derated at 30 degrees, UPS5000-E does not need to be under 40 degrees ()
- A. True
- B. False
Answer: A
NEW QUESTION 97
Which of the following certifications has the PDU8000 precision power distribution cabinet passed: (multiple choice)
- A. Thiel Certification
- B. CCC
- C. CE
Answer: A,B,C
NEW QUESTION 98
Which of the following modules does the UPS5000-E include that can support hot swapping? ( )
- A. Bypass Module
- B. Control Module
- C. Power Module
Answer: A,B,C
NEW QUESTION 99
When selecting UPS cables, the problems to be considered are ()
- A. Number of parallel cables
- B. The rated working voltage and rated insulation voltage of the cable
- C. UPS-related current rating
- D. Voltage drop across the cable path
Answer: A,B,C,D
NEW QUESTION 100
The basic principles of refrigeration of air-cooled and water-cooled air conditioners are the same
- A. True
- B. False
Answer: A
NEW QUESTION 101
The NetEcoo6000 management system can provide monitoring of the cooling power system, and which of the following functions can it provide? (Multiple choice)
- A. It can provide the topological diagram of the chilled water system, showing the operation status of the whole system
- B. Support the display of key equipment indicators on the power distribution topology diagram, which is convenient for users to understand the operation status of the system and important nodes
- C. None of the above is supported
- D. The power distribution system topology diagram can be provided, and the power distribution system diagram of the entire computer room can be displayed
Answer: A,B,D
NEW QUESTION 102
UPS5000-E-75K Half-height cabinet modular UPS modules can be sold redundantly or non-redundantly( )
- A. True
- B. False
Answer: A
NEW QUESTION 103
What is the maximum number of cabinets in the FusionModule500& FusionModule800 modules?
- A. 9,,5
- B. 6, 2
- C. 10, 6
- D. 8, 4
Answer: D
NEW QUESTION 104
The fan control modes supported by the NetCo18000-C series room-level chilled water intelligent cooling products are ( ).
- A. Mixed air control
- B. Differential pressure control
- C. Return air control
- D. Pressure Control
- E. Supply air control
Answer: A,B,C,D,E
NEW QUESTION 105
The RS485 expansion card in the ECC500 collector can provide 5 RS485 interfaces, and each interface can provide 12V DC output.
- A. False
- B. True
Answer: A
NEW QUESTION 106
Regarding the monitoring software NetEco1000U, the following statements are correct ()
- A. Monitor the working status of the UPS in real time and operate the UPS
- B. Email alarm, SMS alarm and other alarm reporting functions
- C. Support USB, SNMP, MODUBUS network communication
- D. SMS alarm needs to be equipped with SMS cat
- E. Provided for free, download and use the answer from the Huawei Support website
Answer: A,B,C,D,E
Explanation:
as needed
NEW QUESTION 107
UPS5000-A about the characteristics of intelligence, which are correct?
- A. The NetEco monitoring software of UPS5000-A supports SMS or E-mail remote alarm
- B. Support NetEco monitoring software, support centralized monitoring of UPS
- C. Support battery intelligent management, effectively prolong battery life
Answer: A,B,C
NEW QUESTION 108
FusionModule2000 maximum number of counters ()
- A. 0
- B. 1
- C. 2
- D. 3
Answer: A
NEW QUESTION 109
What are the fire-fighting linkage functions of FusionModule2000? ( ).
- A. Channel light on
- B. UPS is powered off
- C. Sunroof Flip
- D. The access door is magnetically opened
- E. Air conditioner off
Answer: A,C,D,E
NEW QUESTION 110
Which of the following is correct about the FM800 working condition ( )
- A. Wide temperature condition -40°C~55°C
- B. T1 working condition -20°C-45°C
- C. T3 condition - 10°C ~45°C
- D. Normal temperature condition 0°C-45C
Answer: A
NEW QUESTION 111
Huawei's prefabricated power modules contain the following configurations ( ).
- A. UPS
- B. Compensation Cabinet
- C. Feeder cabinet
- D. Transformer
Answer: A,B,C,D